Analog Glass soap Bubble Flow Meter Specification

  • Measurement Range
  • 0.1 ml/min to 100 ml/min
  • Capacity
  • 0 - 50 ml Milliliter (ML)
  • Equipment Type
  • Soap Bubble Flow Meter
  • Humidity %
  • 0 to 95% RH
  • Flow Rate
  • 0.1 to 100 ml/min
  • Pressure Range
  • Atmospheric Pressure
  • Resolution
  • 1 ml/min
  • Sensor Type
  • Manual Visual (No Electronic Sensor)
  • Temperature Range
  • Ambient, typically 5 C to 40 C Celsius (oC)
  • Material
  • Borosilicate Glass, SS Fittings
  • Power Supply
  • Not Required (Manual Operation)
  • Accuracy
  • 1% of Full Scale gm
  • Display Type
  • Other
  • Range
  • 0.1 to 100 ml/min (Typical)
  • Bubble Tube Length
  • Variable (e.g. 10 cm, 20 cm)
  • Mounting
  • Table Top
  • Operation
  • Manual with Soap Solution
  • Weight
  • 0.5 to 1.5 kg (Model Dependent)
  • Compliance
  • ISO/ASTM Standards
  • Application
  • Calibration of Low Gas Flow (Laboratory Use)
  • Maintenance
  • Easy Cleaning, Replaceable Parts
  • End Connections
  • Stainless Steel or Brass
  • Dimensions
  • Approx. 100 mm x 300 mm x 50 mm
 

Analog Glass soap Bubble Flow Meter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 1 Days
  • Main Domestic Market
  • All India
 

About Analog Glass soap Bubble Flow Meter



Discover the invincible Analog Glass Soap Bubble Flow Metera must-have instrument for precise laboratory calibration of low gas flow. Crafted with splendid borosilicate glass and robust stainless steel/brass fittings, this breathtaking device guarantees 1% full-scale accuracy. Its manual visual sensor ensures reliability without power supply, and competitive pricing makes it an irresistible choice for laboratories, exporters, importers, and service providers across India. Boasting easy cleaning, replaceable parts, and ISO/ASTM compliance, this versatile meter is ready for immediate use. Add to Cart now for unmatched performance.

Versatile Applications and Commercial Use

The Analog Glass Soap Bubble Flow Meter is ideal for calibration of low gas flows in laboratory settings, research centers, and quality control environments. Its general and specific uses cover scientific experimentation, industrial gas measurement, and calibration tasks. This table-top device is designed for use in ambient conditions, making it perfect for universities, commercial laboratories, and production facilities seeking accurate gas flow readings.


Certifications, Payment Options, and Samples

This flow meter complies rigorously with international ISO and ASTM standards, ensuring trustworthy results in every application. Secure shipping and seamless purchase order processing are available for every customer, while competitive asking prices set the standard in the market. Flexible payment terms accommodate a variety of procurement needs, and sample units can be requested to evaluate the products breathtaking performance before bulk purchases.


FAQs of Analog Glass soap Bubble Flow Meter:


Q: How does the Analog Glass Soap Bubble Flow Meter operate?

A: The meter functions manually by passing a soap solution through a glass bubble tube, allowing accurate calibration and measurement of low gas flow rates without the need for any electronic sensors or external power supply.

Q: What types of gases can be measured with this device?

A: It is designed for low-volume gas flow calibration in laboratory settings, suitable for a variety of non-corrosive gases typically used in research and industrial applications.

Q: When should the soap solution be replaced during use?

A: The soap solution should be replaced when the bubble formation becomes inconsistent or contaminated, ensuring continuous, accurate readings and maintaining device hygiene.

Q: Where is the Analog Glass Soap Bubble Flow Meter most commonly used?

A: It is widely utilized in laboratories, universities, calibration facilities, and research institutes where precision gas flow measurements are critical.

Q: What is the process for cleaning and maintaining the flow meter?

A: Maintenance is simpledisassemble the device, rinse the glass and fittings with water or suitable cleaning solution, and reassemble. Replaceable parts make upkeep quick and cost-effective.

Q: What are the main benefits of choosing this soap bubble flow meter?

A: Key benefits include spectacular accuracy, ease of use, compliance with international standards, competitive pricing, and the flexibility to measure a wide range of low gas flows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flow Meters Category

Agriculture Digital Flow Meter

Agriculture Digital Flow Meter

Price 4000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Engineering Plastic

Temperature Range : 10C to 60C

Accuracy : 1.5%

Display Type : Other, Digital LCD

Gas Turbine Flow Meter

Gas Turbine Flow Meter

Minimum Order Quantity : 1 Number

Material : Stainless Steel 304/316

Temperature Range : 20C to +80C

Accuracy : 1.0% of reading

Display Type : Other, LCD Digital Display

Metal Tube Rota meter

Metal Tube Rota meter

Minimum Order Quantity : 1 Number

Material : SS 304/SS 316, Borosilicate Glass (window)

Temperature Range : Up to 250C (Standard design), higher on request

Accuracy : 1.5% FSD

Display Type : Other, Analog Scale (Direct Reading) with Pointer

Digital Electromagnetic Flow Mete

Digital Electromagnetic Flow Mete

Price 5000.0 INR / Set

Minimum Order Quantity : 1 Set

Material : MS

Temperature Range : 120 Celsius (oC)

Accuracy : 0.5 % %

Display Type : Digital Only