Back to top
Insertion Flow Meter
Insertion Flow Meter

Insertion Flow Meter

MOQ : 1 Piece

Insertion Flow Meter Specification

  • Application Media
  • Water, Hot Water, Sewage, Non-corrosive liquids
  • Measurement Range
  • 0-99999 m/h
  • Protection
  • IP65 / IP68 (sensor)
  • Diameter
  • DN100~DN2000 (customizable)
  • Humidity %
  • 85% RH
  • Connectivity Type
  • 4-20 mA, Pulse, RS485 (Modbus)
  • Current Range
  • 4-20mA output
  • Pressure Range
  • 1.6MPa
  • Flow Rate
  • Varies with pipe size and liquid
  • Temperature Range
  • -20C to 60C
  • Frequency
  • 50-60Hz
  • Capacity
  • Wide capacity range
  • Resolution
  • 0.001 m/s
  • Material
  • SS304 / SS316 / ABS
  • Power Supply
  • 24V DC / 220V AC
  • Power Consumption
  • 2W
  • Accuracy
  • 1.5% of reading
  • Display Type
  • LCD Digital Display
  • Range
  • 0.3~12 m/s (typical)
  • Output Signal
  • Pulse / Analog / RS485
  • Data Storage
  • Onboard memory for 2 years
  • Enclosure Material
  • ABS / Aluminum Alloy
  • Repeatability
  • ±0.2%
  • Cable Length
  • Standard 10m (extendable)
  • Power Indicator
  • LED
  • Mounting
  • Hot-tap installation
  • Operating Environment
  • Industrial/Outdoor
  • Equipment Type
  • Insertion Flow Meter
  • Zero Drift
  • < 0.1%
  • Response Time
  • <2s
  • Sensor Type
  • Electromagnetic / Paddle wheel (customized)
 

Insertion Flow Meter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Main Domestic Market
  • All India
 

About Insertion Flow Meter

Specification Electromagnetic FlowMeter

InsertionPipe: SS 304Power Supply : 12 - 60 VDC 

Output: 4 - 20mA

LineSize:DN100- DN2000

Flow Rate : 60,000 LPMElectrodeMaterial:SS316LMeasuring Tube: SS 304ProtectionClass:IP 68

HSNCode:90261010

Flexible and Reliable Measurement

This insertion flow meter is adaptable with customizable sensor types and mounting options, fitting a range of pipe diameters (DN100-DN2000). Its hot-tap installation allows for convenient setup and minimal process downtime, supporting a wide measurement range for diverse industrial applications.


Seamless Integration and Output Options

Data can be accessed and transmitted via analog (4-20 mA), pulse, or RS485 (Modbus) signals. The built-in LCD display provides instant readouts, while onboard memory retains measurement data for up to two years, assisting in efficient data management and compliance.


Robust Construction for Demanding Environments

The flow meter is crafted from high-quality materials such as ABS, Aluminum Alloy, and stainless steel (SS304/SS316), ensuring resilience in industrial and outdoor settings. With IP65/IP68 sensor ratings, it resists dust and water, while functioning reliably across wide temperature and humidity ranges.

FAQ's of Insertion Flow Meter:


Q: How is the insertion flow meter installed in existing pipelines?

A: The flow meter uses a hot-tap installation, allowing it to be inserted into pressurized pipelines without interrupting flow. This approach simplifies retrofitting and maintenance for industrial systems.

Q: What types of liquids can this meter accurately measure?

A: It is designed for a broad range of application media, including water, hot water, sewage, and non-corrosive liquids, making it suitable for varied industrial and municipal uses.

Q: When should I use the electromagnetic versus paddle wheel sensor type?

A: Electromagnetic sensors are preferred for higher accuracy with conductive liquids, while paddle wheel types may be used when cost efficiency is a priority and the liquid has lower conductivity.

Q: Where can I deploy this insertion flow meter?

A: It's ideal for industrial and outdoor environments, thanks to its durable enclosure (IP65/IP68) and wide operating temperature and pressure range. It fits pipe diameters from DN100 to DN2000, making it versatile for both large and small installations.

Q: What benefits does the onboard data storage provide?

A: With onboard memory capable of storing data for two years, users can track flow history for audits, compliance, or diagnostics, reducing the need for frequent manual data retrieval.

Q: How does the meter transmit data to my monitoring system?

A: The device offers multiple output types-including 4-20 mA analog, pulse, and RS485 (Modbus)-allowing seamless integration with most industrial automation and remote monitoring systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flow Meters Category

Swirl Flow Meter

Swirl Flow Meter

Price 1.0 INR / Number

Minimum Order Quantity : 1 Number

Material : Stainless Steel

Display Type : Other, Digital LCD

Temperature Range : 20C to +150C Celsius (oC)

Power Supply : 24V DC

Mechanical Oil Flow Meter

Mechanical Oil Flow Meter

Minimum Order Quantity : 1 Number

Material : Aluminum Alloy Body

Display Type : Other, Mechanical Counter Display

Temperature Range : 10C to +50C

Power Supply : Manual (No external power required)

Analog Glass Soap Bubble Flow Meter

Analog Glass Soap Bubble Flow Meter

Minimum Order Quantity : 100 Pieces

Material : Borosilicate Glass, SS Fittings

Display Type : Other

Temperature Range : Ambient, typically 5 C to 40 C Celsius (oC)

Power Supply : Not Required (Manual Operation)

Digital Electromagnetic Flow Mete

Digital Electromagnetic Flow Mete

Price 5000.0 INR / Set

Minimum Order Quantity : 1 Set

Material : MS

Display Type : Digital Only

Temperature Range : 120 Celsius (oC)

Power Supply : 24 V DC / 230 V AC