Back to top
Insertion Flow Meter
Insertion Flow Meter

Insertion Flow Meter

MOQ : 1 Piece

Insertion Flow Meter Specification

  • Connectivity Type
  • 4-20 mA, Pulse, RS485 (Modbus)
  • Humidity %
  • 85% RH
  • Pressure Range
  • 1.6MPa
  • Temperature Range
  • -20C to 60C
  • Diameter
  • DN100~DN2000 (customizable)
  • Resolution
  • 0.001 m/s
  • Current Range
  • 4-20mA output
  • Capacity
  • Wide capacity range
  • Application Media
  • Water, Hot Water, Sewage, Non-corrosive liquids
  • Measurement Range
  • 0-99999 m/h
  • Flow Rate
  • Varies with pipe size and liquid
  • Protection
  • IP65 / IP68 (sensor)
  • Frequency
  • 50-60Hz
  • Material
  • SS304 / SS316 / ABS
  • Power Supply
  • 24V DC / 220V AC
  • Power Consumption
  • 2W
  • Accuracy
  • 1.5% of reading
  • Display Type
  • LCD Digital Display
  • Range
  • 0.3~12 m/s (typical)
  • Sensor Type
  • Electromagnetic / Paddle wheel (customized)
  • Power Indicator
  • LED
  • Zero Drift
  • < 0.1%
  • Output Signal
  • Pulse / Analog / RS485
  • Repeatability
  • ±0.2%
  • Mounting
  • Hot-tap installation
  • Data Storage
  • Onboard memory for 2 years
  • Enclosure Material
  • ABS / Aluminum Alloy
  • Response Time
  • <2s
  • Cable Length
  • Standard 10m (extendable)
  • Operating Environment
  • Industrial/Outdoor
  • Equipment Type
  • Insertion Flow Meter
 

Insertion Flow Meter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Main Domestic Market
  • All India
 

About Insertion Flow Meter

Specification Electromagnetic FlowMeter

InsertionPipe: SS 304Power Supply : 12 - 60 VDC 

Output: 4 - 20mA

LineSize:DN100- DN2000

Flow Rate : 60,000 LPMElectrodeMaterial:SS316LMeasuring Tube: SS 304ProtectionClass:IP 68

HSNCode:90261010

Flexible and Reliable Measurement

This insertion flow meter is adaptable with customizable sensor types and mounting options, fitting a range of pipe diameters (DN100-DN2000). Its hot-tap installation allows for convenient setup and minimal process downtime, supporting a wide measurement range for diverse industrial applications.


Seamless Integration and Output Options

Data can be accessed and transmitted via analog (4-20 mA), pulse, or RS485 (Modbus) signals. The built-in LCD display provides instant readouts, while onboard memory retains measurement data for up to two years, assisting in efficient data management and compliance.


Robust Construction for Demanding Environments

The flow meter is crafted from high-quality materials such as ABS, Aluminum Alloy, and stainless steel (SS304/SS316), ensuring resilience in industrial and outdoor settings. With IP65/IP68 sensor ratings, it resists dust and water, while functioning reliably across wide temperature and humidity ranges.

FAQ's of Insertion Flow Meter:


Q: How is the insertion flow meter installed in existing pipelines?

A: The flow meter uses a hot-tap installation, allowing it to be inserted into pressurized pipelines without interrupting flow. This approach simplifies retrofitting and maintenance for industrial systems.

Q: What types of liquids can this meter accurately measure?

A: It is designed for a broad range of application media, including water, hot water, sewage, and non-corrosive liquids, making it suitable for varied industrial and municipal uses.

Q: When should I use the electromagnetic versus paddle wheel sensor type?

A: Electromagnetic sensors are preferred for higher accuracy with conductive liquids, while paddle wheel types may be used when cost efficiency is a priority and the liquid has lower conductivity.

Q: Where can I deploy this insertion flow meter?

A: It's ideal for industrial and outdoor environments, thanks to its durable enclosure (IP65/IP68) and wide operating temperature and pressure range. It fits pipe diameters from DN100 to DN2000, making it versatile for both large and small installations.

Q: What benefits does the onboard data storage provide?

A: With onboard memory capable of storing data for two years, users can track flow history for audits, compliance, or diagnostics, reducing the need for frequent manual data retrieval.

Q: How does the meter transmit data to my monitoring system?

A: The device offers multiple output types-including 4-20 mA analog, pulse, and RS485 (Modbus)-allowing seamless integration with most industrial automation and remote monitoring systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flow Meters Category

Agriculture Digital Flow Meter

Agriculture Digital Flow Meter

Price 1.0 INR / Piece

Minimum Order Quantity : 1 Piece

Power Supply : 3V DC (Battery Operated)

Material : Engineering Plastic

Display Type : Other, Digital LCD

Capacity : 99999 Liters (Totalizer)

Digital Oval Gear Flow Meter

Digital Oval Gear Flow Meter

Minimum Order Quantity : 1 Piece

Power Supply : 24V DC / Battery Operated

Material : Aluminium / Stainless Steel

Display Type : Other, Digital, LCD Display

Capacity : Up to 1000 L/min

Thermal Mass Gas Flow Meter

Thermal Mass Gas Flow Meter

Minimum Order Quantity : 1 Number

Power Supply : 24 V DC

Material : Stainless Steel

Display Type : Other, LCD Digital Display

Capacity : Up to 30 Nm/h standard

Ultrasonic Flow Meters

Ultrasonic Flow Meters

Minimum Order Quantity : 1 Piece

Material : Cast Iron & SS

Display Type : Digital Only