Insertion Flow Meter Specification

  • Pressure Range
  • 1.6MPa
  • Application Media
  • Water, Hot Water, Sewage, Non-corrosive liquids
  • Current Range
  • 4-20mA output
  • Flow Rate
  • Varies with pipe size and liquid
  • Protection
  • IP65 / IP68 (sensor)
  • Temperature Range
  • -20C to 60C
  • Diameter
  • DN100~DN2000 (customizable)
  • Humidity %
  • 85% RH
  • Connectivity Type
  • 4-20 mA, Pulse, RS485 (Modbus)
  • Measurement Range
  • 0-99999 m/h
  • Frequency
  • 50-60Hz
  • Resolution
  • 0.001 m/s
  • Capacity
  • Wide capacity range
  • Material
  • SS304 / SS316 / ABS
  • Power Supply
  • 24V DC / 220V AC
  • Power Consumption
  • 2W
  • Accuracy
  • 1.5% of reading
  • Display Type
  • LCD Digital Display
  • Range
  • 0.3~12 m/s (typical)
  • Power Indicator
  • LED
  • Data Storage
  • Onboard memory for 2 years
  • Equipment Type
  • Insertion Flow Meter
  • Enclosure Material
  • ABS / Aluminum Alloy
  • Mounting
  • Hot-tap installation
  • Cable Length
  • Standard 10m (extendable)
  • Zero Drift
  • < 0.1%
  • Output Signal
  • Pulse / Analog / RS485
  • Operating Environment
  • Industrial/Outdoor
  • Response Time
  • <2s
  • Sensor Type
  • Electromagnetic / Paddle wheel (customized)
  • Repeatability
  • ±0.2%
 

Insertion Flow Meter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Main Domestic Market
  • All India
 

About Insertion Flow Meter

Specification Electromagnetic FlowMeter

InsertionPipe: SS 304Power Supply : 12 - 60 VDC 

Output: 4 - 20mA

LineSize:DN100- DN2000

Flow Rate : 60,000 LPMElectrodeMaterial:SS316LMeasuring Tube: SS 304ProtectionClass:IP 68

HSNCode:90261010

Flexible and Reliable Measurement

This insertion flow meter is adaptable with customizable sensor types and mounting options, fitting a range of pipe diameters (DN100-DN2000). Its hot-tap installation allows for convenient setup and minimal process downtime, supporting a wide measurement range for diverse industrial applications.


Seamless Integration and Output Options

Data can be accessed and transmitted via analog (4-20 mA), pulse, or RS485 (Modbus) signals. The built-in LCD display provides instant readouts, while onboard memory retains measurement data for up to two years, assisting in efficient data management and compliance.


Robust Construction for Demanding Environments

The flow meter is crafted from high-quality materials such as ABS, Aluminum Alloy, and stainless steel (SS304/SS316), ensuring resilience in industrial and outdoor settings. With IP65/IP68 sensor ratings, it resists dust and water, while functioning reliably across wide temperature and humidity ranges.

FAQ's of Insertion Flow Meter:


Q: How is the insertion flow meter installed in existing pipelines?

A: The flow meter uses a hot-tap installation, allowing it to be inserted into pressurized pipelines without interrupting flow. This approach simplifies retrofitting and maintenance for industrial systems.

Q: What types of liquids can this meter accurately measure?

A: It is designed for a broad range of application media, including water, hot water, sewage, and non-corrosive liquids, making it suitable for varied industrial and municipal uses.

Q: When should I use the electromagnetic versus paddle wheel sensor type?

A: Electromagnetic sensors are preferred for higher accuracy with conductive liquids, while paddle wheel types may be used when cost efficiency is a priority and the liquid has lower conductivity.

Q: Where can I deploy this insertion flow meter?

A: It's ideal for industrial and outdoor environments, thanks to its durable enclosure (IP65/IP68) and wide operating temperature and pressure range. It fits pipe diameters from DN100 to DN2000, making it versatile for both large and small installations.

Q: What benefits does the onboard data storage provide?

A: With onboard memory capable of storing data for two years, users can track flow history for audits, compliance, or diagnostics, reducing the need for frequent manual data retrieval.

Q: How does the meter transmit data to my monitoring system?

A: The device offers multiple output types-including 4-20 mA analog, pulse, and RS485 (Modbus)-allowing seamless integration with most industrial automation and remote monitoring systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flow Meters Category

Metal Tube Rota meter

Metal Tube Rota meter

Price 1.0 INR / Number

Minimum Order Quantity : 1 Number

Material : SS 304/SS 316, Borosilicate Glass (window)

Power Supply : Not Required (Operates mechanically)

Display Type : Other, Analog Scale (Direct Reading) with Pointer

Measurement Range : 0.0210000 LPH (for liquids), 0.5250 Nm3/hr (for gases)

Gas Turbine Flow Meter

Gas Turbine Flow Meter

Price 1.0 INR / Number

Minimum Order Quantity : 1 Number

Material : Stainless Steel 304/316

Power Supply : 24V DC, Battery Operated (optional)

Display Type : Other, LCD Digital Display

Measurement Range : 0.58000 m/h

Wall Mount Ultrasonic Flow Meter

Wall Mount Ultrasonic Flow Meter

Price 1.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : ABS plastic enclosure

Power Supply : 220V AC / 24V DC

Display Type : Other, LCD display

Measurement Range : DN15~DN6000 pipe size

Oval Gear Flow Meter

Oval Gear Flow Meter

Price 1.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : MS

Power Supply : Electric